Code SC362-02
Description
TD sensor output error: Lower limit (C) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
Causes
TD sensor connector missing/dropout
Remedy
1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness (disconnection, etc.)
3. If the sensor is defective, replace the development unit.