Code: 12.8:10
Description:
Printmech: Hannibal2 24V failure. Check Spit-on roller motor and Primer motor
Causes:
The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Check the Spit-on roller motor and Primer motor. 2. Check the Printmech PCA.
Code: 12.9:10
Description:
Printmech: Hannibal3 24V failure. Check Inner lights array 1
Causes:
The 24V cable from Printmech to Inner lights array 1 has a problem Printmech PCA is damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Check the Inner lights array 1. 2. Check the Printmech PCA.
Code: 13.3:10
Description:
Printmech 12V_BULLI_2 to Vapor Removal PCA out of range
Causes:
The Printmech 12V_BULLI_2 to Vapor Removal PCA is out of range.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cable to Vapor Removal PCA. 2. Check the Printmech PCA.
Code: 14.73:01
Description:
Curing power regulator V lower than 60: V lower than 60
Causes:
Heater Control AC Input (RCCB, AC Voltage Outlet, AC Power Cord) Heater Control.
Remedy:
Call agent: 1. Check that both Residual Circuit Breakers (RCCBs) are Powered and ON. 2. Check/Reseat both Power Cords. Service engineer: 1. Check AC Voltage at customer's site (180-264Vac). 2. Reseat/Replace cables to Heater Control's AC input. 3. Replace the Heater Control.
Code: 14.74:01
Description:
Curing power regulator V lower than 140
Causes:
V lower than 140
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Check the input voltage.
Code: 14.75:01
Description:
Curing power regulator V bigger than Vmax
Causes:
V bigger than Vmax
Remedy:
1. Check the input voltage. 2. Run Service "Curing system monitor".
Code: 14.76:11
Description:
Curing power regulator V could not be read
Causes:
Curing Control PCA Cable to Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/Replace Curing Control PCA Cable to Heater Control.
Code: 14.77:10
Description:
Curing power regulator control signal failure
Causes:
Control signal failure
Remedy:
Service engineer: • Replace the Control PCA to Heater Control and Control PCA cables.
Code: 14.80:10
Description:
Curing power regulator current not null
Causes:
Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Replace the Heater Control.

Code: 14.81:10
Description:
Curing power regulator current too high
Causes:
Heaters, Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Check heaters with a tester and replace heaters if necessary (shortcut). 3. Replace the Heater Control.
Code: 14.82:10
Description:
Curing power regulator shortcut
Causes:
Heaters, Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Check heaters with a tester and replace heaters if necessary (shortcut). 3. Replace the Heater Control.
Code: 14.83:11
Description:
Curing power regulator open circuit
Causes:
Heater Control to Curing Power Interconnect PCA Cable. Curing Power Interconnect PCA Curing Cable. Curing Resistor.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/Replace the Heater Control to Curing Power Interconnect PCA Cables. 3. Reseat/Replace Curing Power Interconnect PCA Curing Cable. 4. Reseat/Replace all Curing Resistors connectors.
Code: 14.87:10
Description:
Curing power regulator OverTemp
Causes:
Power regulator OverTemp.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. If the SE appears frequently, replace the Heater Control.
Code: 14.88:10
Description:
Curing power regulator overvoltage or shortcut
Causes:
Regulator overvoltage or shortcut.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Check resistor module values, If they are ok, check installation.
Code: 14.89:10
Description:
Curing power regulator relay damaged
Causes:
Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Replace de Heater Control.
Code: 15.20:10
Description:
Cable or Resistor shortcircuit from any PZ or vapor resistor
Causes:
Shortcircuit from Any PZ or vapor resistor.
Remedy:
Service engineer: • Check the PZ resistors, the Vapor resistors, or cable shortcircuits. Replace the affected part.
Code: 15.31:10
Description:
PZ resistor 1: Cable or resistor shortcircuit
Causes:
Cable or resistor shortcircuit.
Remedy:
Service engineer: • Check the PZ resistor 1 or cable shortcircuit.
Code: 15.32:10
Description:
PZ resistor 2: Cable or resistor shortcircuit
Causes:
Cable or resistor shortcircuit.
Remedy:
Service engineer: • Check the PZ resistor 2 or cable shortcircuit.
Code: 15.33:10
Description:
PZ resistor 3: Cable or resistor shortcircuit
Causes:
Cable or resistor shortcircuit.
Remedy:
Service engineer: • Check the PZ resistor 3 or cable shortcircuit.
Code: 15.41:11
Description:
PZ resistor 1: Not connected
Causes:
PZ Heaters Cable PZ Resistor 1 Air Curtain and Printzone Heaters Control PCA.
Remedy:
• Restart the printer. Service engineer: 1. Reseat/Replace Air Curtain and Printzone Heaters Control PCA to PZ Heaters cable. 2. Reseat/Replace PZ Resistor 1.
Code: 15.42:11
Description:
PZ resistor 2: Not connected
Causes:
PZ resistor 2 disconnected or damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: • Check that PZ 2 resistor is properly connected. If it is, then replace PZ 2 resistor.
Code: 15.43:11
Description:
PZ resistor 3: Not connected
Causes:
PZ resistor 3 disconnected or damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: • Check that PZ 3 resistor is properly connected. If it is, then replace PZ 3 resistor.
Code: 15.51:03
Description:
PZ resistor 1: Out of range
Causes:
Resistor out of range.
Remedy:
Service engineer: • Measure the PZ 1 resistance. Replace in case of resistance out of range.
Code: 15.52:03
Description:
PZ resistor 2: Out of range
Causes:
Resistor out of range.
Remedy:
Service engineer: • Measure the PZ 2 resistance. Replace in case of resistance out of range.
Code: 15.53:03
Description:
PZ resistor 3: Out of range
Causes:
Resistor out of range.
Remedy:
Service engineer: • Measure the PZ 3 resistance. Replace in case of resistance out of range.

Code: 15.60:10
Description:
PZ fan fault or not connected
Causes:
Fan fault or not connected
Remedy:
Service engineer: • Check that the PZ fans are properly connected. If they are, then replace them.
Code: 15.61:10
Description:
PZ fan 1 fault or not connected
Causes:
PZ fan 1 disconnected or damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: • Check that PZ 1 fan is properly connected. If it is, then replace PZ 1 fan.
Code: 15.62:10
Description:
PZ fan 2 fault or not connected
Causes:
PZ fan 2 disconnected or damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: • Check that PZ 2 fan is properly connected. If it is, then replace PZ 2 fan.
Code: 15.63:10
Description:
PZ fan 3 fault or not connected
Causes:
PZ fan 3 disconnected or damaged.
Remedy:
Service engineer: • Check that PZ 3 fan is properly connected. If it is, then replace PZ 3 fan.
Code: 15.69:10
Description:
More than 1 PZ fan fault or not connected
Causes:
PZ Heaters Fan Cable PZ Resistor Fan 1 Air Curtain and Printzone Heaters Control PCA.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Reseat/Replace Air Curtain and Printzone Heaters Control PCA to PZ Heaters Fan cable. 2. Reseat/Replace PZ Resistor Fan 1.
Code: 15.71:10
Description:
PZ fan 1: fan or cable damaged
Causes:
Fan or cable damaged.
Remedy:
Service engineer: • Replace the PZ fan 1.
Code: 15.72:10
Description:
PZ fan 2: fan or cable damaged
Causes:
Fan or cable damaged.
Remedy:
Service engineer: • Replace the PZ fan 2.
Code: 15.73:10
Description:
PZ fan 3: fan or cable damaged
Causes:
Fan or cable damaged.
Remedy:
Service engineer: • Replace the PZ fan 3.

Code: 15.79:10
Description:
More than 1 PZ fan or cable damaged
Causes:
More than 1 PZ fan or cable damaged.
Remedy:
Service engineer: • Replace the PZ fans.
Code: 16.01:00
Description:
Curing System unable to warm up in the pre-defined amount of time
Causes:
Ambient temperature below 15oC. Low AC Voltage. Fans (Curing, Air Curtain, PZ). Curing Resistors. Curing Temperature Sensor. Curing Pressure Sensor.
Remedy:
1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check if the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor". 4. Check all Fans (Curing, Air Curtain, PZ), all spinning and no obstruction. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.02:00
Description:
Curing system: cool down timeout
Causes:
Ambient temperature above 30C Fans (Curing, Air Curtain, PZ).
Remedy:
Service engineer: 1. The environmental ambient temperature is too hot or is outside the operational specification of the printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters etc. 2. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.
Code: 16.03:00
Description:
Curing system: high temperature error
Causes:
Ambient temperature above 30oC, Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy:
1. The environmental ambient temperature is too hot or is outside the operational specification of the printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters etc. 2. Run Service "Curing system monitor”. 3. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 4. Reseat/Replace Curing Resistors. 5. Reseat/Replace Curing Temperature Sensors. 6. Reseat/Replace Curing Pressure Sensor.
Code: 16.04:00
Description:
Curing system: low temperature error
Causes:
Ambient temperature below 15oC, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy:
1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor. 4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.05:00
Description:
Curing system: temperature sensor error
Causes:
Curing Control PCA Temperature Sensors Cable Temp. Sensors.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/replace Curing Control PCA Temperature Sensors Cable. 3. Reseat/replace Temp. Sensors.
Code: 16.07:03
Description:
Curing system: warm up timeout (uniformity)
Causes:
Ambient temperature below 15oC, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy:
1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor. 4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.11:10
Description:
Curing System: Temperature sensor 1 failure or not connected
Causes:
Curing Control PCA Sensors cable Temp. sensor 1.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Reseat/replace Curing Control Sensors cable. 2. Reseat/replace Temp. sensor 1.

Code: 16.12:10
Description:
Curing System: Temperature sensor 2 failure or not connected
Causes:
Temperature sensor 2.
Remedy:
Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 2.
Code: 16.13:10
Description:
Curing System: Temperature sensor 3 failure or not connected
Causes:
Temperature sensor 3.
Remedy:
Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 3.
Code: 16.14:10
Description:
Curing System: Temperature sensor 4 failure or not connected
Causes:
Temperature sensor 4.
Remedy:
Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 4.
Code: 16.31:10
Description:
Curing system: Fan 1 fault
Causes:
Curing system: Fan 1 fault.
Remedy:
Call agent: • Restart the printer. Service engineer: • Replace module 1.
Code: 16.32:10
Description:
Curing system: Fan 2 fault
Causes:
Curing system: Fan 2 fault.
Remedy:
Call agent: • Restart the printer. Service engineer: • Replace module 2.
Code: 16.33:10
Description:
Curing system: Fan 3 fault
Causes:
Curing system: Fan 3 fault.
Remedy:
Call agent: • Restart the printer. Service engineer: • Replace module 3.


苏州相城区哪里有修打印机的?电话0512696l6769,苏州相城区复印机出租电话696l6769,hp硒鼓墨盒批发
苏州相城区哪里有修hp打印机的?

热门图文

相关资料补充


热门关注
· hp latex 310常见故障代码描述,英文手册1

· hp latex 330常见故障代码描述,英文手册5

· hp latex 330常见故障代码描述,英文手册4

· hp latex 330常见故障代码描述,英文手册3

· hp latex 330常见故障代码描述,英文手册2

· hp latex 330常见故障代码描述,英文手册1

· hp latex 360常见故障代码描述,英文手册5

· hp latex 360常见故障代码描述,英文手册4

· hp latex 360常见故障代码描述,英文手册3

· hp latex 360常见故障代码描述,英文手册2

· hp latex 360常见故障代码描述,英文手册1

· hp officejet pro x451常见故障代码描述,英文手册

· hp officejet pro x476 mfp常见故障代码描述,英文手册

· hp officejet pro x551常见故障代码描述,英文手册

· hp officejet pro x576 mfp常见故障代码描述,英文手册

· hp1025后盖感应器在哪里?

· hp401机器总提示碳粉盒区域卡纸大概是哪里的问题

· hp1136报错e8是什么问题

· hp2025打印机出现红底黑字问题

· hp1025是一样的问题,开机不自检,一直闪烁倒三角感叹号

· hp400卡纸报碳粉盒区域卡纸,其实纸已经出来四分之三还多点了

· hp1025打印机打印左侧有3个黑点,上下有规律

· hp2025无法打印彩色。测试页正常

· hp laserjetm1136mfp指示灯一直亮

· hp3600报错59.c0错误,解决一例

· hp laserjet 4700n/dn/dtn 安装后提示“59.c0”错误是什么原因

· hp2025打印机出现59.c0代码,问题原因解析

· hp m251n打印机报错59.c0错误

· hp5550打印机开机报59.c0错误故障分析

· hp2100打印机开机出现:重新启动打印。如果问题仍然存在,请致电hp支持中心如何解

推荐文章
· hp2025颜色平面定位传感器错误

· hplaserjet9050dn错误代码49.2f83error

· hp2520hc电源灯闪并亮喊叹号

· hpm128fn加完粉后一直报黑色碳粉不足

· hpm202dw更换硒鼓出现不兼容的墨粉盒

· hpcp1025无法识别芯片

· hp128老提示更换硒鼓

· hp175a开机显示正在初始化后就显示通道卡纸

· hp1606dn提醒指示灯、就绪指示灯和“确定”指示灯亮起

· hpmfp175报49错误

· hplaserjetp1106就绪灯和错误灯同时亮

· hpn126打印机总是自动初始化

· hpm128fn双灯闪烁无显示

· hpm1136打印机激光器扫描架清理

· hpm1136mfp显示hp,然后下面两个灯一直在双闪,无法打印,什么情况

· hp5025错误代码59.20

· hp定影器错误关闭后然后打开

· hpm2727一直初始化

· hpcp5225恢复出厂设置

· hp177fw一体机新机提示安装成像鼓

· 佳能mf4452报警:e2020002接触式传感器hp错误,回路故障

· hp2055扫描打印复印一体机,显示printingdocument然后无反映故障

· hp1005纸刚出定影组件就卡住

· hp2055d开机提示52扫描仪错误

· hp128提示文档进纸器拾取错误

· hpm128fp故障灯一直闪控制面板无显示

· hp126nw提示正在使用用过的碳粉盒

· hpt790绘图仪错误代码79:03

· 79errorhp2600

· hp176开机时为什么电源灯旁的感叹号闪烁

· hpm1213nf打印一张通路卡纸

· hp1055cmip地址查询

· hp-mfpm176n加了粉还提示墨粉量低

· hp3630墨盒加墨水图解

· hp3035错误信息49.ff04

· hplaserjet1100serues显示感叹号

· hpm176一直提示三角感叹号错误是怎么回事

· hp1112开机灯闪烁

· hp系统错误7904关闭电源如果问题仍存在,请致电hp支持中心

· hpp2055d提示49err3d910c8怎么解决

· hpm1005复印薄的文稿有黑影

· hp226dw提示扫描仪错误17关闭然后打开

· hp1280电源灯不亮的真正原因

· hpp1606n不进纸,是什么问题

· hp2025彩色打印机报错59是哪里的问题

· ricohprintersc680

· hpm128fp开机一直显示正在初始化

· hp1319f屏幕 无显

· hp m1005一体机安装程序错误,rpc服务器不可用

· hp m1005 开机报scanner error 20错误,故障原因