Code: F2 76
Description:
Developing unit CRUM trouble (Magenta)
Causes:
CRUM read/write error
Remedy:
Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
Code: F2 77
Description:
Developing unit CRUM trouble (Yellow)
Causes:
CRUM read/write error
Remedy:
Case 1 Cause Improper connection or disconnection of the connector and the harness between the PCU and the CRUM. Check & Remedy Check the connector and the harness between the PCU and the CRUM. Case 2 Cause Developing unit trouble Check & Remedy Replace the developing unit. Case 3 Cause Control PWB (PCU) trouble Check & Remedy Replace the PCU PWB.
Code: F2 78
Description:
Trouble of image density sensor for registration (Transfer belt surface reflection ratio abnormality)
Causes:
Before starting registration, the transfer belt surface is scanned with the image density sensor to adjust the sensor gain so that the output becomes a fixed value. However, when the sensor gain is changed, the value is not within the specified range.
Remedy:
Case 1 Cause Image density sensor trouble, disconnection of the harness between the PCU PWB and the image density sensor, dirt on the image density sensor. Check & Remedy Check the sensor and the harness. Case 2 Cause Calibration plate solenoid operation trouble Check & Remedy Check the calibration plate solenoid operation. Case 3 Cause Insufficient cleaning of the transfer belt. Check & Remedy Check the transfer belt surface.
Code: F2 80
Description:
Half-tone process control 1st batch trouble (Black)
Causes:
First step operation error during half-tone process control
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Code: F2 81
Description:
Half-tone process control 1st batch trouble (Cyan)
Causes:
First step operation error during half-tone process control
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.

Code: F2 82
Description:
Half-tone process control 1st batch trouble (Magenta)
Causes:
First step operation error during half-tone process control
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Code: F2 83
Description:
Half-tone process control 1st batch trouble (Yellow)
Causes:
First step operation error during half-tone process control
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Code: F2 84
Description:
Half-tone process control 2nd batch trouble (Black)
Causes:
Second step operation error during half-tone process control
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Code: F2 85
Description:
Half-tone process control 2nd batch trouble (Cyan)
Causes:
Second step operation error during half-tone process control
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Code: F2 86
Description:
Half-tone process control 2nd batch trouble (Magenta)
Causes:
Second step operation error during half-tone process control
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Code: F2 87
Description:
Half-tone process control 2nd batch trouble (Yellow)
Causes:
Second step operation error during half-tone process control
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Code: F2 90
Description:
Half-tone process limit error
Causes:
The difference between the correction value after execution of half-tone process control and the previous correction value exceeds the specified max. value of each color.
Remedy:
Common Check Use SIM 44-2 to adjust the process control sensor gain. Case 1 Cause When "Error" occurs in the gain adjustment of SIM 44- 2: 1. Disconnection of the harness between the PCU PWB and the image density sensor. 2. Image density sensor dirt/trouble Check & Remedy 1. Check connection of the harness between the PCU PWB and the image density sensor. 2. Clean/replace the image density sensor. Case 2 Cause When SIM 44-2 gain adjustment is completed: Insufficient cleaning of the transfer belt, calibration plate solenoid operation trouble Check & Remedy Check the drum surface and the belt surface.
Code: F3 12
Description:
Cassette 1 lift-up trouble
Causes:
LUD1 does not turn on within the specified time.
Remedy:
Case 1 Cause LUD1 sensor trouble, disconnection of harness among the PCU PWB, the lift-up unit, and the paper feed unit. Check & Remedy Check LUD1, its harness, and the connector. Case 2 Cause Cassette 1 lift-up motor trouble Check & Remedy Check the lift-up unit.
Code: F9 00
Description:
ICU-PRT communication trouble (ICU detection)
Causes:
Communication establishment error, framing, parity, protocol error
Remedy:
Case 1 Cause Defective connection of the ICU/PRT PWB communication connector, defective harness between the ICU PWB and the PRT PWB, defective ICU PWB/ PRT PWB Check & Remedy Check connection and the harness between the ICU PWB and the MFP PWB. Check the machine earth. Replace the ICU or the PRT PWB.
Code: F9 01
Description:
PRT DRAM trouble
Causes:
DRAM in the PRT PWB cannot be accessed.
Remedy:
Case 1 Cause Defective DRAM, defective installation of the DRAM Check & Remedy Replace the DRAM. Check connection of the DRAM.
Code: F9 03
Description:
NIC port check error
Causes:
Defective connection of the NIC connector, defective NIC PWB, defective PRT PWB
Remedy:
Check the NIC connector again. Replace the HDD. Replace the PRT PWB.
Code: F9 20
Description:
HDD trouble (PRT controller detection)
Causes:
The HDD (option) does not operate normally in the machine with the HDD.
Remedy:
Case 1 Cause Defective connection of the HDD connector, defective HDD, defective PRT PWB Check & Remedy Check the HDD again. Replace the HDD. Replace the PRT PWB.
Code: H2 00
Description:
Thermistor open (HL1)
Causes:
Thermistor open
Remedy:
Case 1 Cause Disconnection of the fusing section connector Check & Remedy Check the connector and the harness between the thermistor and the control PWB. Case 2 Cause The fusing unit is not installed. Check & Remedy Install the fusing unit. Case 3 Cause Thermistor trouble, control PWB trouble, AC power supply trouble Check & Remedy Replace the thermistor or the control PWB. Check the AC power supply.
Code: H2 01
Description:
Thermistor open (HL2)
Causes:
Thermistor open
Remedy:
Case 1 Cause Disconnection of the fusing section connector Check & Remedy Check the connector and the harness between the thermistor and the control PWB. Case 2 Cause The fusing unit is not installed. Check & Remedy Install the fusing unit. Case 3 Cause Thermistor trouble, control PWB trouble, AC power supply trouble Check & Remedy Replace the thermistor or the control PWB. Check the AC power supply.
Code: H3 00
Description:
Fusing section high temperature trouble (THS1)
Causes:
The fusing temperature exceeds 230°C.
Remedy:
Common Check Use SIM 5-2 to check the heater lamp flashing operation. Case 1 Cause The heater lamp flashes properly with SIM 5-2. Thermistor trouble, disconnection of the fusing section connector Check & Remedy Check the thermistor and its harness. Cancel the error with SIM 14. Case 2 Cause The heater lamp keeps ON with SIM 5-2. Control PWB trouble, AC power supply trouble Check & Remedy Check the AC PWB and the control PWB lamp control circuit. Cancel the error with SIM 14.
Code: H3 01
Description:
Fusing section high temperature trouble (THS2)
Causes:
The fusing temperature exceeds 230°C.
Remedy:
Common Check Use SIM 5-2 to check the heater lamp flashing operation. Case 1 Cause The heater lamp flashes properly with SIM 5-2. Thermistor trouble, disconnection of the fusing section connector Check & Remedy Check the thermistor and its harness. Cancel the error with SIM 14. Case 2 Cause The heater lamp keeps ON with SIM 5-2. AC power supply trouble, control PWB trouble Check & Remedy Check the AC PWB and the control PWB lamp control circuit. Cancel the error with SIM 14.
Code: H4 00
Description:
Fusing section low temperature trouble (HL1)
Causes:
The fusing temperature is not reached within the specified time after turning on the power relay.
Remedy:
Common Check Use SIM 5-2 to check the heater lamp flashing operation. Case 1 Cause The heater lamp flashes properly with SIM 5-2. Thermistor trouble, PCU PWB (thermistor input circuit) trouble Check & Remedy Check the thermistor and its harness. Check the PCU PWB thermistor input circuit. Cancel the error with SIM 14. Case 2 Cause The heater lamp keeps ON with SIM 5-2. Heater lamp trouble, thermostat trouble, interlock switch trouble, AC power supply trouble, PCU PWB (lamp control circuit) trouble Check & Remedy Check for disconnection of the heater lamp and the thermostat. Check the interlock switch. Check the AC PWB and the PUC PWB lamp control circuit. Cancel the error with SIM 14.
Code: H4 01
Description:
Fusing section low temperature trouble (HL2)
Causes:
The fusing temperature is not reached within the specified time after turning on the power relay.
Remedy:
Common Check Use SIM 5-2 to check the heater lamp flashing operation. Case 1 Cause The heater lamp flashes properly with SIM 5-2. Thermistor trouble, PCU PWB (thermistor input circuit) trouble Check & Remedy Check the thermistor and its harness. Check the PCU PWB thermistor input circuit. Cancel the error with SIM 14. Case 2 Cause The heater lamp keeps ON with SIM 5-2. Heater lamp trouble, thermostat trouble, interlock switch trouble, AC power supply trouble, PCU PWB (lamp control circuit) trouble Check & Remedy Check for disconnection of the heater lamp and the thermostat. Check the interlock switch. Check the AC PWB and the PUC PWB lamp control circuit. Cancel the error with SIM 14.
Code: H5 01
Description:
Five continuous detections of POD1 not-reached jam
Causes:
POD1 not-reached jams are detected for five times continuously.
Remedy:
Case 1 Cause A fusing jam is not canceled completely. (Jam paper remains inside the machine.) Check & Remedy Check remaining jam paper (winding). Cancel the error with SIM 14. Case 2 Cause POD1 sensor trouble, or harness disconnection Check & Remedy Check POD1 sensor harness. Cancel the error with SIM 14. Case 3 Cause Improper installation of the fusing unit Check & Remedy Check installation of the fusing unit. Cancel the error with SIM 14.
Code: H8 01
Description:
Fusing unit initial detection trouble
Causes:
Fusing unit initial detection trouble
Remedy:
Case 1 Cause Disconnection of the connector Check & Remedy Check connection of the fusing unit initial sensor. Check connection of the connector and the harness to the PCU PWB. Case 2 Cause Connector harness trouble Check & Remedy Check for disconnection of the harness. Case 3 Cause Fusing unit trouble Check & Remedy Replace the fusing unit.
Code: L1 00
Description:
Mirror feed trouble
Causes:
Mirror feed is not completed within the specified time.
Remedy:
Case 1 Cause Mirror unit trouble, mirror wire breakage Check & Remedy Use SIM 1-1 to check the mirror operation.
Code: L3 00
Description:
Mirror return trouble
Causes:
Mirror return is not completed within the specified time.
Remedy:
Case 1 Cause Mirror unit trouble, mirror wire breakage Check & Remedy Use SIM 1-1 to check the mirror operation.
Code: L4 02
Description:
Paper feed motor lock trouble
Causes:
In warm-up, or in canceling a jam, the paper feed motor is rotated, and the lock signal is not detected within 1sec.
Remedy:
Case 1 Cause Paper feed motor trouble, disconnection of the harness between the PCU PWB and the paper feed motor, control circuit trouble Check & Remedy Use SIM 6-1 to check the paper feed motor operation. Check the harness and the connector between the PCU PWB and the paper feed motor.
Code: L4 06
Description:
Transfer belt lift motor trouble
Causes:
When the belt motor lifts up or down, the change in the belt home position sensor characteristics is not detected within the specified time. (When the motor lifts up, the lower limit sensor remains ON after the specified time.) (When the motor lifts down, the lower limit sensor does not turn on after the specified time.)
Remedy:
Case 1 Cause Belt lift motor trouble, disconnection of the harness between the PCU PWB and the belt lift motor, control circuit trouble Check & Remedy Use SIM 6-1 to check the belt lift motor operation. Check the harness and the connector between the PCU PWB and the belt lift motor.

Code: L4 07
Description:
Transfer belt motor trouble
Causes:
1) Before driving the drum, the calibration plate is opened with the process control BK sensor, and light is emitted with the gain value of 0 and with the light emitting quantity fixed to 120. The average of ten light quantities repeats to be 5 or less for 3 times continuously. 2) Immediately after driving the drum, the calibration plate is opened with the process control BK sensor, and one whole turn of the belt surface is scanned with the gain value of 0 and with the light emitting quantity at the optimum value (120 - 50). The difference between the max. value and the min. value of the scanned data is 5 or less.
Remedy:
Case 1 Cause Transfer belt motor connector disconnection, process control sensor connector disconnection, process control BK sensor defect, defective connection of the harness between the PCU PWB and the transfer belt motor, defective control circuit Check & Remedy Check the transfer belt motor operation with SIM25-1. Check the process control sensor operation with SIM44-2. Check the harness and the connector between the PCU PWB and the transfer belt motor.
Code: L4 11
Description:
Shift motor trouble
Causes:
When initializing the shift motor, the change in the shift motor home position sensor characteristics is not detected within the specified time.
Remedy:
Case 1 Cause Shift motor trouble, disconnection of the harness between the PCU PWB and the shift motor, control circuit trouble Check & Remedy Use SIM 6-1 to check the shift motor operation. Use SIM 30-1 to check the shift motor home position sensor. Check the harness and the connector between the PCU PWB and the shift motor.
Code: L8 01
Description:
Full wave signal not provided
Causes:
The full wave signal is not provided.
Remedy:
Case 1 Cause PCU PWB trouble Check & Remedy Replace the PCU PWB. Case 2 Cause Power supply unit trouble Check & Remedy Replace the power supply unit. Case 3 Cause Harness trouble Check & Remedy Check connection of the harness and the connector.
Code: L8 02
Description:
Full wave signal width abnormality
Causes:
An abnormality of the full wave signal frequency is detected. (The detected frequency is 65kHz or above, or 45kHz or below.)
Remedy:
Case 1 Cause PCU PWB trouble Check & Remedy Replace the PCU PWB. Case 2 Cause Power supply unit trouble Check & Remedy Replace the power supply unit. Case 3 Cause Harness trouble Check & Remedy Check connection of the harness and the connector.
Code: L8 04
Description:
Main power switch abnormality detection
Causes:
Though the PCU program is operating (the power is supplied), the main power switch OFF is detected.
Remedy:
Case 1 Cause Main power switch trouble Check & Remedy Replace the main power switch. Case 2 Cause Power supply unit trouble Check & Remedy Replace the power supply unit. Case 3 Cause Harness trouble Check & Remedy Check connection of the harness and the connector.
Code: PF 00
Description:
RIC copy inhibit signal reception
Causes:
The copy inhibit signal from RIC (host) is received.
Remedy:
Case 1 Cause Depends on a judgment by the host. Check & Remedy Make notification to the host. Use SIM 27-1 to ignore.
Code: U0 00
Description:
ICU-OPE communication trouble (ICU/OPE detection)
Causes:
Communication establishment error, framing/parity/protocol error ROM version mismatching
Remedy:
Case 1 Cause Disconnection of the operation panel communication connector of the ICU/MFP PWB, harness trouble between the ICU PWB and the MFP PWB. Check & Remedy Check the connector and the harness between the ICU PWB and the MFP PWB. Case 2 Cause ICU/MFP PWB trouble Check & Remedy Check grounding of the machine. Replace the ICU PWB or the MFP PWB. Case 3 Cause When the OPE-ROM without security functions is installed for the ICUROM with security kit functions. Check & Remedy Check the ROM version, and replace it if necessary.
Code: U1 02
Description:
RTC read trouble
Causes:
Abnormal value is read from the RTC on the ICU PWB.
Remedy:
Case 1 Cause RTC circuit abnormality Check & Remedy Set the time again with the key operation, and check that time advances properly. Check the RTC circuit.

Code: U2 00
Description:
EEPROM read/write error (ICU detection)
Causes:
EEPROM version error EEPROM write error
Remedy:
Case 1 Cause EEPROM trouble. EEPROM is not initialized. Check & Remedy 1. Check that the EEPROM is properly set. 2. Use SIM 16 to cancel the error. Case 2 Cause ICU PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the ICU PWB. 3. Use SIM 16 to cancel the error.
Code: U2 11
Description:
EEPROM check sum error (ICU detection)
Causes:
EEPROM (ICU) check sum error
Remedy:
Case 1 Cause EEPROM trouble Check & Remedy 1. Check that the EEPROM is properly set. 2. Use SIM 16 to cancel the error. Case 2 Cause Control circuit freeze by noises. ICU PWB EEPROM access circuit trouble. Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the ICU PWB. 3. Use SIM 16 to cancel the error.
Code: U2 30
Description:
Production No. data discrepancy
Causes:
The production No. recorded in the PCU differs from that recorded in the ICU.
Remedy:
Case 1 Cause EEPROM is not exchanged when replacing the PCU/ICU PWB. Check & Remedy Check that the EEPROM is properly installed. When replacement, check that the EEPROM before replacement is inserted to the board after replacement.
Code: U2 80
Description:
EEPROM read/write error (SCN)
Causes:
EEPROM version error EEPROM write error
Remedy:
Case 1 Cause EEPROM trouble, Insertion of EEPROM which is not initialized or defective. Check & Remedy 1. Check that the EEPROM is properly inserted. 2. Use SIM 16 to cancel the error. Case 2 Cause SCN PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the SCN PWB. 3. Use SIM 16 to cancel the error.
Code: U2 81
Description:
Adjustment value check sum error (SCN)
Causes:
EEPROM (SCN) check sum error
Remedy:
Case 1 Cause EEPROM trouble Check & Remedy 1. Check that the EEPROM is properly inserted. 2. Use SIM 16 to cancel the error. Case 2 Cause SCN PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the SCN PWB. 3. Use SIM 16 to cancel the error.
Code: U2 90
Description:
EEPROM read/write error (PCU)
Causes:
EEPROM version error EEPROM write error
Remedy:
Case 1 Cause EEPROM trouble, Insertion of EEPROM which is not initialized or defective. Check & Remedy 1. Check that the EEPROM is properly inserted. 2. Use SIM 16 to cancel the error. Case 2 Cause PCU PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the PCU PWB. 3. Use SIM 16 to cancel the error.
Code: U2 91
Description:
Adjustment value check sum error (PCU)
Causes:
EEPROM (PCU) check sum error
Remedy:
Case 1 Cause EEPROM trouble Check & Remedy 1. Check that the EEPROM is properly inserted. 2. Use SIM 16 to cancel the error. Case 2 Cause Control circuit freeze caused by noises, PCU PWB EEPROM access circuit trouble Check & Remedy 1. To prevent against deletion of the counter data and the adjustment data, record them with the simulation. (When a printer option is installed, use SIM 22-1 to record the counter data and the adjustment data.) 2. Replace the PCU PWB. 3. Use SIM 16 to cancel the error.
Code: U4 02
Description:
ADU alignment plate operation abnormality
Causes:
The alignment plate does not move from the home position within 1sec when it must move. Return to the home position is not detected for 5sec or more.
Remedy:
Case 1 Cause Home position sensor trouble Check & Remedy Use SIM 9-2 to detect the home position sensor. Case 2 Cause Alignment plate shift motor trouble Check & Remedy Use SIM 9-4 to check the alignment plate operation. Case 3 Cause Disconnection of the harness between the ADU control PWB and the motor sensor. Check & Remedy Check connection of the harness between the ADU control PWB and the motor sensor. Case 4 Cause Alignment plate operation belt, gear breakage or improper adjustment Check & Remedy Remove the ADU, and check for breakage of the gear and the belt.

Code: U5 00
Description:
ADF communication trouble
Causes:
Communication test error when turning on the power or after canceling the exclusive simulation. Communication error with the ADF
Remedy:
Case 1 Cause Improper connection or disconnection of the connector and the harness Check & Remedy Check the connector and the harness in the communication line. Turn OFF/ON the power to cancel the error. Case 2 Cause ADF control PWB trouble, control PWB (MFP) trouble, malfunction caused by noises Check & Remedy Check the ADF control PWB and the control PWB (MFP). Turn OFF/ON the power to cancel the error.
Code: U5 01
Description:
ADF resist sensor trouble
Causes:
ADF resist sensor detection trouble
Remedy:
Case 1 Cause Sensor trouble Check & Remedy Use SIM 2-2 to check the resist sensor detection. Case 2 Cause Disconnection of the harness in the ADF. Check & Remedy Check the harness in the ADF. Case 3 Cause ADF control PWB trouble Check & Remedy Replace the ADF control PWB.
Code: U5 02
Description:
ADF repulsion sensor trouble
Causes:
ADF paper feed/reverse sensor detection trouble
Remedy:
Case 1 Cause Sensor trouble Check & Remedy Use SIM 2-2 to check the resist sensor detection. Case 2 Cause Disconnection of the harness in the ADF. Check & Remedy Check the harness in the ADF. Case 3 Cause ADF control PWB trouble Check & Remedy Replace the ADF control PWB.
Code: U5 03
Description:
ADF timing sensor trouble
Causes:
ADF timing sensor detection trouble
Remedy:
Case 1 Cause Sensor trouble Check & Remedy Use SIM 2-2 to check the resist sensor detection. Case 2 Cause Disconnection of the harness in the ADF. Check & Remedy Check the harness in the ADF. Case 3 Cause ADF control PWB trouble Check & Remedy Replace the ADF control PWB.
Code: U5 11
Description:
Paper feed motor operation abnormality
Causes:
Paper feed motor operation abnormality
Remedy:
Case 1 Cause Motor lock, motor RPM abnormality, Over current to the motor, ADF control PWB trouble Check & Remedy Use SIM 2-2/3/4 to check the paper feed motor operation.
Code: U6 00
Description:
Desk communication trouble
Causes:
Desk communication error, communication test error when turning on the power or after canceling the exclusive simulation.
Remedy:
Case 1 Cause Improper connection or disconnection of the connector and the harness. Check & Remedy Check the connector and the harness in the communication line. Turn OFF/ON the power to cancel the error. Case 2 Cause Desk control PWB trouble, control PWB (PCU) trouble, malfunction caused by noises Check & Remedy Turn OFF/ON the power to cancel the error.
Code: U6 01
Description:
Desk cassette 1 lift-up trouble
Causes:
DLUD1 does not turn on within the specified time.
Remedy:
Case 1 Cause DLUD1 sensor trouble, paper feed unit harness disconnection Check & Remedy Check DLUD1 and the harness and the connector. Case 2 Cause Cassette 1 lift-up motor trouble, desk PWB, lift-up unit trouble Check & Remedy Check the lift-up unit.
Code: U6 02
Description:
Desk cassette 2 lift-up trouble
Causes:
DLUD2 does not turn on within the specified time.
Remedy:
Case 1 Cause DLUD2 sensor trouble, paper feed unit harness disconnection Check & Remedy Check DLUD2 and the harness and the connector. Case 2 Cause Cassette 2 lift-up motor trouble, desk PWB, lift-up unit trouble Check & Remedy Check the lift-up unit.

Code: U6 03
Description:
Desk cassette 3 lift-up trouble
Causes:
DLUD3 does not turn on within the specified time.
Remedy:
Case 1 Cause DLUD3 sensor trouble, paper feed unit harness disconnection Check & Remedy Check DLUD3 and the harness and the connector. Case 2 Cause Cassette 3 lift-up motor trouble, desk PWB, lift-up unit trouble Check & Remedy Check the lift-up unit.
Code: U6 10
Description:
Desk transport motor trouble
Causes:
Desk transport motor operation trouble
Remedy:
Case 1 Cause Motor lock, motor RPM abnormality, Over current to the motor, console finisher control PWB trouble Check & Remedy Use SIM 3-3 to check the staple motor operation.
Code: U7 00
Description:
RIC communication trouble
Causes:
RIC communication error, communication test error when turning on the power or after canceling the exclusive simulation.
Remedy:
Case 1 Cause Improper connection or disconnection of the connector and the harness Check & Remedy Check the connector and the harness in the communication line. Turn OFF/ON the power to cancel the error. Case 2 Cause RIC control PWB trouble, control PWB (PCU) trouble, malfunction caused by noises Check & Remedy Turn OFF/ON the power to cancel the error.
Code: UC 02
Description:
CPT-ASIC trouble (MFP PWB trouble)
Causes:
Access abnormality to CPT-ASIC (ASIC does not operate normally.)
Remedy:
Case 1 Cause CPT-ASIC abnormality MFP PWB abnormality Check & Remedy Turn OFF/ON repeatedly. If the trouble is not canceled, replace the MFP PWB.

热门图文

相关资料补充


热门关注
· sharp arc262m常见故障代码描述,英文手册2

· sharp arc262m常见故障代码描述,英文手册1

· sharp arc270常见故障代码描述,英文手册4

· sharp arc270常见故障代码描述,英文手册3

· sharp arc270常见故障代码描述,英文手册2

· sharp arc270常见故障代码描述,英文手册1

· sharp arc280常见故障代码描述,英文手册4

· sharp arc280常见故障代码描述,英文手册3

· sharp arc280常见故障代码描述,英文手册2

· sharp arc280常见故障代码描述,英文手册1

· sharp arc330常见故障代码描述,英文手册4

· sharp arc330常见故障代码描述,英文手册3

· sharp arc330常见故障代码描述,英文手册2

· sharp arc330常见故障代码描述,英文手册1

· sharp arc360p常见故障代码描述,英文手册2

· sharp arc360p常见故障代码描述,英文手册1

· sharp arf151常见故障代码描述,英文手册

· sharp arf152常见故障代码描述,英文手册

· sharp arf160常见故障代码描述,英文手册

· sharp arf161常见故障代码描述,英文手册

· sharp arf200常见故障代码描述,英文手册

· sharp arf201常见故障代码描述,英文手册

· sharp arm150常见故障代码描述,英文手册

· sharp arm155常见故障代码描述,英文手册

· sharp arm160常见故障代码描述,英文手册

· sharp arm161常见故障代码描述,英文手册

· sharp arm162常见故障代码描述,英文手册

· sharp arm165常见故障代码描述,英文手册

· sharp arm200常见故障代码描述,英文手册

· sharp arm201常见故障代码描述,英文手册

推荐文章
· sharp4018打印机小三角灯一直闪问题

· sharpar-4821d打印机出现了那个三角的红色一直亮着怎么回事

· sharpmx-m2608n无法网络打印,设置方法

· toshiba2830显示c970故障代码

· sharpmx-m850打印机出错代码:f2-00怎清除

· sharp2608复印机错误代码l4-11是什么意思怎么解决

· sharp打印机型号是:ar1808s,最近经常出现2f现象,请问是什状况呀?

· sharp2608复印机怎么清除f2-40代码

· toshiba打印机3040c请求维修ce40什么意思

· toshiba复印机错误代码2e66什么意思

· sharpdx-2008uc错误代码f2-40是什么意思

· sharpm2608n无法连接设备请查看设备是否处于扫描模式

· 施乐扫描错误异常结束(018-543)sharednameerrorinserver

· sharpar2348n显示错误

· sharpar2348n常见问题报错解决方法带图文

· sharpar2048s问题大全

· shngc-1202-00下载

· sharp1808s扫描仪显示u-2

· sharp2048n呼叫维修

· sharp2348n恢复出厂

· sharp打印机出现错误代码h5-1是设么意思

· sharp打印复印一体机上面显示有个人的形状然后红灯了是什么意思

· 东芝(toshiba)a4多功能一体机e-studio300d加粉流程图

· sharp2618nc发生错误。代码:l4-43

· sharpar2048打印机显示需要用户干预打印不成怎么办

· toshiba2303卡纸怎去除

· 东芝toshiba2303a打印机提示简易设置调整错误请按确定键重试

· sharp-mx2018uc 报l14-04代码,那位大师指点一下

· toshiba2303a复印机出现e140代码是什么意思

· sharp ar2008d打印清楚。复印很淡,手动清楚,调整方法

· sharp1808s扫描出现u-2

· toshibastudio2303a换碳粉

· sharp mxm700u常见故障代码描述,英文手册2

· sharp mxm654fn常见故障代码描述,英文手册1

· sharp mxm654fn常见故障代码描述,英文手册2

· sharp mxm654fn常见故障代码描述,英文手册3

· sharp mxm623u常见故障代码描述,英文手册1

· sharp mxm623u常见故障代码描述,英文手册2

· sharp mxm620u常见故障代码描述,英文手册01

· sharp mxm620u常见故障代码描述,英文手册02

· sharp mxm564n常见故障代码描述,英文手册01

· sharp mxm564n常见故障代码描述,英文手册02

· sharp mxm550u常见故障代码描述,英文手册01

· sharp mxm550u常见故障代码描述,英文手册02

· sharp mxm503n常见故障代码描述,英文手册1

· sharp mxm503n常见故障代码描述,英文手册2

· sharp mxm502n常见故障代码描述,英文手册2

· sharp mxm502n常见故障代码描述,英文手册1

· sharp mxm465n常见故障代码描述,英文手册2

· sharp mxm465n常见故障代码描述,英文手册1