Code: F2-71
Description:
Improper toner cartridge detection (CYAN)
Causes:
An improper toner cartridge is inserted. (The main unit detects a toner cartridge of a different specification.) Toner cartridge trouble. PCU PWB trouble.
Remedy:
Replace the toner cartridge. Replace the PCU PWB.
Code: F2-72
Description:
Improper toner cartridge detection (MAGENTA)
Causes:
An improper toner cartridge is inserted. (The main unit detects a toner cartridge of a different specification.) Toner cartridge trouble. PCU PWB trouble.
Remedy:
Replace the toner cartridge. Replace the PCU PWB.
Code: F2-73
Description:
Improper toner cartridge detection (YELLOW)
Causes:
An improper toner cartridge is inserted. (The main unit detects a toner cartridge of a different specification.) Toner cartridge trouble. PCU PWB trouble.
Remedy:
Replace the toner cartridge. Replace the PCU PWB.
Code: F2-74
Description:
Toner cartridge CRUM error (BLACK)
Causes:
Toner cartridge (CRUM) trouble. PCU PWB trouble. Connector/harness trouble.
Remedy:
Replace the toner cartridge. Replace the PCU PWB. Connector/harness trouble.
Code: F2-75
Description:
Toner cartridge CRUM error (CYAN)
Causes:
Toner cartridge (CRUM) trouble. PCU PWB trouble. Connector/harness trouble.
Remedy:
Replace the toner cartridge. Replace the PCU PWB. Connector/harness trouble.
Code: F2-76
Description:
Toner cartridge CRUM error (MAGENTA)
Causes:
Toner cartridge (CRUM) trouble. PCU PWB trouble. Connector/harness trouble.
Remedy:
Replace the toner cartridge. Replace the PCU PWB. Connector/harness trouble.
Code: F2-77
Description:
Toner cartridge CRUM error (YELLOW)
Causes:
Toner cartridge (CRUM) trouble. PCU PWB trouble. Connector/harness trouble.
Remedy:
Replace the toner cartridge. Replace the PCU PWB. Connector/harness trouble.
Code: F2-78
Description:
Registration image density sensor trouble (Transfer belt substrate reflection rate abnormality)
Causes:
Image density (registration) sensor trouble (Sensor sensitivity adjustment trouble). PCU PWB trouble. Connection trouble of the connector and the harness. Image density (registration) sensor dirt. Transfer belt dirt, scratch.
Remedy:
Replace the image density (registration) sensor. Replace the PCU PWB. Harness and connector connection trouble. Clean the image density (registration) sensor. Clean or replace the transfer belt.
Code: F3-12
Description:
Paper feed tray 1 lift operation trouble
Causes:
LUD1 is not turned ON within the specified time. CLUD1 sensor trouble Paper feed tray 1 lift unit trouble. PCU PWB trouble. Harness and connector connection trouble.
Remedy:
Check connection of the harness and the connector of LUD1. Replace the lift-up unit. Replace the PCU PWB.
Code: H2-00
Description:
Thermister open trouble (TH_UM_AD2)
Causes:
Thermister trouble. PCU PWB trouble Connection trouble of the connector and the harness. Fusing unit not installed.
Remedy:
Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble.
Code: H2-01
Description:
Thermister open trouble (TH_LM)
Causes:
Thermister trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Fusing unit not installed.
Remedy:
Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble.
Code: H2-02
Description:
Sub thermister open trouble (TH_US)
Causes:
Thermister trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Fusing unit not installed.
Remedy:
Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble.
Code: H2-03
Description:
Compensation thermister open trouble (TH_UM_AD1)
Causes:
Thermister trouble. PCU PWB trouble Connection trouble of the connector and the harness. Fusing unit not installed.
Remedy:
Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble.
Code: H2-04
Description:
Thermister open (TH_EX1)
Causes:
Thermister trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Fusing unit not installed.
Remedy:
Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble.
Code: H2-05
Description:
Thermister open (TH_EX2)
Causes:
Thermister trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Fusing unit not installed.
Remedy:
Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble.
Code: H3-00
Description:
Fusing section high temperature trouble (TH_UM)
Causes:
The fusing temperature exceeds the specified level. Thermister trouble. PCU PWB trouble Connection trouble of the connector and the harness. Power unit trouble.
Remedy:
Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble. Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble. Replace the power unit.

Code: H3-01
Description:
Fusing section high temperature trouble (TH_LM)
Causes:
The fusing temperature exceeds the specified level. Thermister trouble. PCU PWB trouble.Harness and connector connection trouble. Power unit trouble.
Remedy:
Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble. Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble. Replace the power unit.
Code: H3-02
Description:
Fusing section high temperature trouble (TH_US)
Causes:
The fusing temperature exceeds the specified level. Thermister trouble. PCU PWB trouble Connection trouble of the connector and the harness. Power unit trouble.
Remedy:
Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble. Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble. Replace the power unit.
Code: H3-04
Description:
Fusing section high temperature trouble (TH_EX1)
Causes:
The fusing temperature exceeds the specified level. Thermister trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Power unit trouble. Fusing unit not installed.
Remedy:
Replace the power unit. Replace the PCU PWB. Harness and connector connection trouble. Use SIM14 to cancel the trouble.
Code: H3-05
Description:
Fusing section high temperature trouble (TH_EX2)
Causes:
The fusing temperature exceeds the specified level. Thermister trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Power unit trouble.
Remedy:
Replace the thermister. Replace the PCU PWB. Harness and connector connection trouble. Replace the power unit. Use SIM14 to cancel the trouble.
Code: H4-00
Description:
Fusing section low temperature trouble (TH_UM_AD2)
Causes:
The fusing temperature does not reach the specified level within the specified time from turning ON the power relay. Thermister trouble. Heater lamp trouble. PCU PWB trouble. Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy:
Replace the thermister. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble.
Code: H4-01
Description:
Fusing section low temperature trouble (TH_LM)
Causes:
The fusing temperature does not reach the specified level within the specified time from turning ON the power relay. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy:
Replace the thermister. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble.
Code: H4-02
Description:
Fusing section low temperature trouble (TH_US)
Causes:
The fusing temperature does not reach the specified level within the specified time from turning ON the power relay. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy:
Replace the thermister. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble.
Code: H4-04
Description:
Fusing section low temperature trouble (TH_EX)
Causes:
The specified temperature is not reached within the specified time from starring warm-up. Thermister trouble. Heater lamp trouble. PCU PWB trouble. Thermostat trouble. Power unit trouble.
Remedy:
Use SIM5-2 to check the operation of the heater lamp. Replace the thermister. Replace the PCU PWB. Check connection of the connector and the harness. Replace the heater lamp. Replace the power unit. Use SIM14 to cancel the trouble.
Code: H4-30
Description:
Thermister input circuit trouble (TH_UM)
Causes:
The values of TH_UM_AD1 and TH_UM_AD2 do not exceed the specified value (50 counts in AD value) within the specified time from turning ON the HL_UM. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble
Remedy:
Replace the thermister. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp. Use SIM14 to cancel the trouble.
Code: H5-01
Description:
5 times continuous POD1 not-reach jam
Causes:
A fusing jam is not canceled completely. (A jam paper remains.) POD1 sensor trouble. Fusing unit installation trouble. Connector, harness connection trouble. PCU PWB trouble
Remedy:
Replace the POD1 sensor. Check the installing position of the fusing unit. Replace the fusing unit. Check connection of the connector and the harness. Replace the PCU PWB. Use SIM14 to cancel the trouble.
Code: H7-10
Description:
Fusing low temperature recovery trouble (TH_UM_AD2).
Causes:
The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy:
Replace the thermister. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp.
Code: H7-11
Description:
Fusing low temperature recovery trouble (TH_LM)
Causes:
The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy:
Replace the thermister. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp.
Code: H7-12
Description:
Fusing low temperature recovery trouble (TH_US)
Causes:
The fusing temperature does not reach the specified level within the specified time from stopping a job due to fall in the fusing temperature. Thermister trouble. Heater lamp trouble. PCU PWB trouble Thermostat trouble. Connector, harness connection trouble. Power unit trouble. Interlock switch trouble.
Remedy:
Replace the thermister. Replace the heater lamp. Replace the PCU PWB. Replace the thermostat. Check connection of the connector and the harness. Replace the power unit. Replace the interlock switch. Use SIM5-2 to check the flashing operation of the heater lamp.
Code: H7-14
Description:
Low temperature trouble (TH_EX) in reset operation after JOB stop due to a fall in the fusing temperature during a JOB.
Causes:
The specified temperature is not reached within the specified time in reset operation of the fusing temperature. Thermister trouble. Heater lamp trouble. PCU PWB trouble. Thermostat trouble. Connector, harness connection trouble. Power unit trouble.
Remedy:
Use SIM5-2 to check the operation of the heater lamp. Replace the thermister. Replace the PCU PWB. Check connection of the connector and the harness. Replace the heater lamp. Replace the power unit. Use SIM14 to cancel the trouble.
Code: H8-00
Description:
Fusing unit initial detection trouble
Causes:
The initial detection fuse is not blown off though it is conducted for the specified time. Fusing unit trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
Remedy:
Use SIM6-51 to check the operations of the [FUCRU] fuse blowing circuit. Use SIM30-1 to check the [FUCRU] initial detection input signal. Replace the fusing unit. Replace the PCU PWB. Check connection of the connector and the harness.
Code: L1-00
Description:
Scanner feed trouble
Causes:
Scanner feed is not completed within the specified time. Scanner unit trouble. SCU PWB trouble Scanner control PWB trouble. Harness and connector connection trouble. Scanner home position sensor trouble. Scanner motor trouble.
Remedy:
Use SIM1-1 to check the scan operation. Replace the scanner unit. Replace the SCU PWB. Check connection of the connectors and the harness. Replace the scanner home position sensor. Replace the scanner motor.
Code: L3-00
Description:
Scanner return trouble
Causes:
Scanner return is not completed within the specified time. Scanner unit trouble. SCU PWB trouble Scanner control PWB trouble. Harness and connector connection trouble. Scanner home position sensor trouble. Scanner motor trouble.
Remedy:
Use SIM1-1 to check the scan operation. Replace the scanner unit. Replace the SCU PWB. Check connection of the connectors and the harness. Replace the scanner home position sensor. Replace the scanner motor.
Code: L4-03
Description:
Fusing motor lock trouble
Causes:
The motor lock signal is detected during rotation of the fusing motor. Fusing motor trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
Remedy:
Use Sim6-1 to check the operation of the fusing motor. Replace the fusing motor. Replace the PCU PWB. Check connection of the connector and the harness.
Code: L4-04
Description:
Developing motor trouble (BLACK)
Causes:
The motor lock signal is detected during rotation of the developing motor. Developing motor trouble. Harness and connector connection trouble. PCU PWB trouble Developing unit trouble.
Remedy:
Use SIM25-1 to check the operation of the developing motor. Replace the developing motor. Check connection of the connectors and the harness. Replace the PCU PWB. Replace the developing motor. Replace the developing unit.
Code: L4-05
Description:
Developing motor trouble (COLOR)
Causes:
The motor lock signal is detected during rotation of the developing motor. Developing motor trouble. Harness and connector connection trouble. PCU PWB trouble Developing unit trouble.
Remedy:
Use SIM25-1 to check the operation of the developing motor. Replace the developing motor. Check connection of the connectors and the harness. Replace the PCU PWB. Replace the developing motor. Replace the developing unit.
Code: L4-06
Description:
Transfer unit lift trouble
Causes:
Transfer unit position sensor trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Transfer unit separation clutch operation trouble. Primary transfer belt unit is not installed.
Remedy:
Use SIM6-3 to check the separating operation of the transfer unit. Install the primary transfer belt unit. Replace the transfer unit position sensor. Replace the PCU PWB. Harness and connector connection trouble. Replace the transfer unit separation clutch.
Code: L4-12
Description:
Secondary transfer separation trouble
Causes:
A change in the state of the separation sensor is not detected in the specified time during separating operation of the secondary transfer unit. Secondary transfer unit separation mechanism trouble Secondary transfer unit separation motor trouble. Secondary transfer unit separation sensor trouble. Connection trouble of the connector and the harness. PCU PWB trouble.
Remedy:
Check the operation of the secondary transfer unit separation mechanism. Replace the secondary transfer unit separation motor. Replace the secondary transfer unit separation sensor. Check connection of the connector and the harness. Replace the PCU PWB.
Code: L4-16
Description:
Fusing pressure release trouble
Causes:
No change in the fusing pressure release sensor signal is detected within the specified time after turning ON the fusing pressure release solenoid. Fusing pressure release sensor trouble. Fusing pressure release solenoid trouble. Fusing pressure release level F, R trouble. PCU PWB trouble. Fusing motor trouble. Connection trouble of the connector and the harness.
Remedy:
Replace the fusing pressure release sensor. Replace the fusing pressure release solenoid. Replace the fusing pressure release lever F, R. Replace the PCU PWB. Fusing motor trouble. Harness and connector connection trouble.
Code: L4-29
Description:
HDD fan trouble
Causes:
The fan lock signal is detected during rotation of the HDD fan. HDD fan trouble. MFP PWB trouble. Connection trouble of the connector and the harness.
Remedy:
Use SIM6-2 to check the operation of the fan motor. Replace the HDD fan. Replace the MFP PWB. Replace the connector or the harness.

Code: L4-31
Description:
Paper exit cooling fan trouble
Causes:
The fan operation signal is not detected within the specified time in the paper exit cooling fan operation. Paper exit cooling fan trouble. PCU PWB trouble Connection trouble of the connector and the harness.
Remedy:
Check connection of the connectors and the harness. Use SIM6-2 to check the rotating operation of the fan. Replace the paper exit cooling fan. Replace the PCU PWB.
Code: L4-32
Description:
Power source cooling fan trouble
Causes:
The fan operation signal is not detected within the specified time in the power cooling fan operation. Power cooling fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
Remedy:
Use SIM6-2 to check the rotating operation of the fan. Replace the power cooling fan. Replace the PCU PWB. Check/replace the connector or the harness.
Code: L4-34
Description:
LSU fan trouble
Causes:
The fan rotation signal is not detected in the specified time during operation of the LSU fan. Connection trouble of the connector and the harness. LSU fan trouble. LSU control PWB trouble.
Remedy:
Use Sim6-2 to check the operation of the fan. Check connection of the connector and the harness. Replace the LSU fan. Replace the LSU control PWB.
Code: L4-35
Description:
Fusing cooling fan trouble
Causes:
The fan operation signal is not detected within the specified time in the fusing cooling fan operation. Fusing cooling fan trouble. PCU PWB trouble Connection trouble of the connector and the harness.
Remedy:
Use SIM6-2 to check the rotating operation of the fan. Replace the fusing cooling fan. Replace the PCU PWB. Harness and connector connection trouble.
Code: L4-50
Description:
Process fan trouble
Causes:
The fan operation signal is not detected within the specified time in the process fan operation. Process fan trouble. PCU PWB trouble Connection trouble of the connector and the harness.
Remedy:
Check that the fan is rotating after turning ON the power. Replace the process fan. Replace the PCU PWB. Harness and connector connection trouble.
Code: L4-51
Description:
Process fan 2 trouble
Causes:
The fan operation signal is not detected within the specified time in the process fan 2 operation. Process fan trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
Remedy:
Check that the fan is rotating after turning ON the power. Replace the process fan 2. Replace the PCU PWB. Check connection of the connector and the harness.
Code: L6-10
Description:
Polygon motor trouble
Causes:
The motor does not reach the specified rpm in 7 sec after starting rotation of the polygon motor. Polygon motor trouble. LSU control PWB trouble. Connection trouble of the connector and the harness.
Remedy:
Use SIM61-1 to check the operation of the polygon motor. Check connection of the connectors and the harness. Replace the polygon motor. Replace the LSU. Replace the LSU control PWB.
Code: L8-01
Description:
Full wave signal detection error
Causes:
No full wave signal is detected. PCU PWB trouble Power unit trouble. Connection trouble of the connector and the harness.
Remedy:
Replace the PCU PWB. Replace the power unit. Check connection of the connectors and the harness.

Code: L8-02
Description:
Full wave signal error
Causes:
An abnormality in the full wave signal frequency is detected. (The frequency is detected as 65Hz or above, or 45Hz or less.)PCU PWB trouble. Power unit trouble. Connection trouble of the connector and the harness. Power frequency, waveform abnormality.
Remedy:
Replace the PCU PWB. Replace the power unit. Check connection of the connectors and the harness. Check the power waveform.
Code: L8-20
Description:
MFP PWB - Mother board communication error
Causes:
Mother board PWB - MFPC PWB connection trouble. MFP PWB trouble. Replace the mother board.
Remedy:
Check connection between the mother board and the MFPC PWB. Check the earth line of the main unit. Replace the MFPC PWB. Replace the mother board.
Code: PC--
Description:
Personal counter not detected
Causes:
The personal counter is not installed. The personal counter is not detected.
Remedy:
Check connection of the connectors and the harness. Replace the SCU PWB.
Code: U1-01
Description:
Battery trouble
Causes:
1) Battery life 2) Battery circuit abnormality
Remedy:
Check to confirm that the battery voltage is about 2.0V or above. Use SIM13 to cancel the trouble.
Code: U2-00
Description:
MFP EEPROM read/write error
Causes:
MFP PWB EEPROM trouble. EEPROM socket contact trouble. MFP PWB trouble. Strong external noises.
Remedy:
Use SIM16 to cancel the error. Replace the MFP PWB EEPROM. Replace the MFP PWB. Check the power environment.
Code: U2-05
Description:
HDD/MFP PWB SRAM contents inconsistency
Causes:
The HDD or the MFP PWB which differs from that before turning OFF the power is installed. HDD trouble. MFP PWB trouble.
Remedy:
Use SIM16 to cancel the error. If there is backup data (export data by device cloning), import it.
Code: U2-10
Description:
MFP PWB SRAM user authentication index check sum error
Causes:
SRAM user index information (user authentication basic data) check sum error. MFP PWB SRAM trouble. Strong external noises.
Remedy:
Use SIM16 to cancel the error. Transfer the user index information data in the HDD to the SRAM. Replace the MFP PWB.
Code: U2-11
Description:
MFP PWB EEPROM counter check sum error
Causes:
MFP PWB EEPROM trouble. EEPROM socket contact trouble. MFP PWB trouble. Strong external noises.
Remedy:
Use SIM16 to cancel the error. Replace the MFP PWB.

Code: U2-22
Description:
MFP PWB SRAM memory check sum error
Causes:
The identifier which controls the communication management table stored in the SRAM and the FAX soft switch is not detected correctly. MFP PWB SRAM trouble. MFP PWB trouble. Strong external noises.
Remedy:
Since the data of the communication management table and the FAX soft switch stored in the SRAM are initialized when an error occurs, register the deleted data again individually. Use SIM16 to cancel the error. Replace the MFP PWB.
Code: U2-23
Description:
MFP PWB SRAM memory individual data check sum error
Causes:
The check sum value for individual data of the communication table and the sender registration does not match. MFP PWB SRAM trouble. MFP PWB trouble. Strong external noises.
Remedy:
Turn OFF/ON the power to initialize the data related to the content of check sum error. Since the registered contents are deleted, register the deleted contents again. Use SIM16 to cancel the error. Replace the MFP PWB.
Code: U2-24
Description:
MFP PWB SRAM memory user authentication counter check sum error
Causes:
MFP PWB SRAM trouble. MFP PWB trouble. Strong external noises.
Remedy:
Use SIM16 to cancel the error.
Code: U2-30
Description:
MFP PWB and PCU PWB manufacturing No. data inconsistency
Causes:
Inconsistency between the manufacturing No. saved in the PCU PWB and that in the MFP PWB. When replacing the PCU PWB or the MFP PWB, the EEPROM which was mounted on the PWB before replacement is not mounted on the new PWB. MFP PWB trouble. PCU PWB trouble
Remedy:
Check that the EEPROM is properly set. Check to confirm that the EEPROM which was mounted on the PWB before replacement is mounted on the new PWB. Use SIM16 to cancel the error. Replace the MFP PWB. Replace the PCU PWB.
Code: U2-50
Description:
HDD user authentication data check sum error
Causes:
HDD trouble. MFP PWB trouble. Strong external noises.
Remedy:
Initialize the data (one-touch, group, program, etc.) related to the check sum error by turning OFF/ON the power. Since the registered contents are deleted, register the deleted contents again. Use SIM16 to cancel the error. Replace the HDD. Replace the MFP PWB.
Code: U2-80
Description:
SCU PWB EEPROM read/write error
Causes:
SCU PWB EEPROM trouble. SCU PWB trouble. EEPROM socket contact trouble.
Remedy:
Replace the SCU PWB EEPROM. Replace the SCU PWB. Check contact of the EEPROM socket. Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values. Use SIM16 to cancel the trouble.
Code: U2-81
Description:
SCU PWB EEPROM check sum error
Causes:
SCU PWB EEPROM trouble. Installation of non-initialized EEPROM. SCU PWB trouble. EEPROM socket contact trouble.
Remedy:
Replace the SCU PWB EEPROM. Replace the SCU PWB. Check contact of the EEPROM socket. Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values. Use SIM16 to cancel the trouble.
Code: U2-90
Description:
PCU PWB EEPROM read/write error
Causes:
PCU PWB EEPROM trouble. Installation of non-initialized EEPROM. PCU PWB trouble EEPROM socket contact trouble.
Remedy:
Replace the PCU PWB EEPROM. Replace the PCU PWB. Check contact of the EEPROM socket. Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values. Use SIM16 to cancel the trouble.

Code: U2-91
Description:
PCU PWB EEPROM check sum error
Causes:
PCU PWB EEPROM trouble. Installation of non-initialized EEPROM. PCU PWB trouble EEPROM socket contact trouble.
Remedy:
Replace the PCU PWB EEPROM. Replace the PCU PWB. Check contact of the EEPROM socket. Put down the counter/adjustment values in the simulation to prevent against loss of the counter data and the adjustment values. Use SIM16 to cancel the trouble.
Code: U6-00
Description:
PCU PWB - Desk paper feed unit communication error
Causes:
Error when testing the communication line after turning ON the power or canceling the simulation. Connector, harness connection trouble. Desk control PWB trouble. PCU PWB trouble Strong external noises.
Remedy:
Turn OFF/ON the power to cancel. Check the connector and the harness in the communication line. Replace the desk control PWB. Replace the PCU PWB.
Code: U6-01
Description:
Desk paper feed tray 1 lift trouble
Causes:
D1ULD does not turn ON within the specified time when lift-up operation. D1ULD sensor trouble. Desk control PWB trouble. Lift unit trouble. Connection trouble of the connector and the harness. PCU PWB trouble
Remedy:
Replace the D1ULD sensor. Replace the desk control PWB. Replace the lift unit. Harness and connector connection trouble. Replace the PCU PWB.
Code: U6-02
Description:
Desk paper feed tray 2 lift trouble
Causes:
D2ULD does not turn ON within the specified time when lift-up operation. D2ULD sensor trouble. Desk control PWB trouble. Lift unit trouble. Connection trouble of the connector and the harness. PCU PWB trouble
Remedy:
Replace the D2ULD sensor. Replace the desk control PWB. Replace the lift unit. Harness and connector connection trouble. Replace the PCU PWB.
Code: U6-03
Description:
Desk paper feed tray 3 lift trouble
Causes:
The D3ULD sensor is not turned ON within the specified time during lift-up operation. D3ULD sensor trouble. Desk control PWB trouble. Lift unit trouble. Connection trouble of the connector and the harness. PCU PWB trouble.
Remedy:
Replace the D3ULD sensor. Replace the desk control PWB. Replace the lift unit. Check connection of the connector and the harness. Replace the PCU PWB.
Code: U6-10
Description:
Desk paper feed unit paper transport motor trouble
Causes:
Desk paper feed motor trouble (motor lock, motor rpm abnormality, overcurrent to the motor). Desk control PWB trouble. Connection trouble of the connector and the harness.
Remedy:
Use SIM4-3 to check the operation of the desk transport motor. Replace the desk control PWB. Replace the desk paper feed motor. Harness and connector connection trouble.
Code: U6-50
Description:
Desk - Main unit combination trouble
Causes:
Improper combination between the main unit and the desk. Desk control PWB trouble.
Remedy:
Install a desk which is proper for the main unit mode. Replace the desk control PWB.
Code: U7-50
Description:
MFP PWB - Vendor machine communication error
Causes:
Improper setting of the vendor machine specifications (SIMI26-3). Vendor machine trouble. MFP PWB trouble. Connector, harness connection trouble. Strong external noises.
Remedy:
Cancel the error by turning OFF/ON the power. Check the connector and the harness in the communication line. Change the specifications of the vendor machine (SIM26-3). Replace the LCC control PWB. Replace the MFP PWB.

Code: U7-51
Description:
Vendor machine error
MFP (Notification of a trouble from the serial vendor)
Causes:
Serial vendor machine trouble. Connector, harness connection trouble.
Remedy:
Err.XX" is displayed on the operation panel of the vendor. (XX is the detail code.) Repair the vendor machine referring to the detail code. Check the connector and the harness in the communication line.K
Code: UC-02
Description:
IPD ASIC (CPT) error
Causes:
IPD ASIC (CPT) operation error SCN PWB trouble.
Remedy:
Replace the SCN PWB.
Code: UC-20
Description:
IPD ASIC (DOCC) error
Causes:
IPD ASIC (DOCC) operation error SCN PWB trouble.
Remedy:
Replace the SCN PWB.

热门图文

相关资料补充


热门关注
· sharp mx3500n常见故障代码描述,英文手册1

· sharp mx3501n常见故障代码描述,英文手册2

· sharp mx3501n常见故障代码描述,英文手册1

· sharp mx3550n常见故障代码描述,英文手册4

· sharp mx3550n常见故障代码描述,英文手册3

· sharp mx3550n常见故障代码描述,英文手册2

· sharp mx3550n常见故障代码描述,英文手册1

· sharp mx3560n常见故障代码描述,英文手册4

· sharp mx3560n常见故障代码描述,英文手册3

· sharp mx3560n常见故障代码描述,英文手册2

· sharp mx3560n常见故障代码描述,英文手册1

· sharp mx3570n常见故障代码描述,英文手册4

· sharp mx3570n常见故障代码描述,英文手册3

· sharp mx3570n常见故障代码描述,英文手册2

· sharp mx3570n常见故障代码描述,英文手册1

· sharp mx3600fn常见故障代码描述,英文手册3

· sharp mx3600fn常见故障代码描述,英文手册2

· sharp mx3600fn常见故障代码描述,英文手册1

· sharp mx3610n常见故障代码描述,英文手册3

· sharp mx3610n常见故障代码描述,英文手册2

· sharp mx3610n常见故障代码描述,英文手册1

· sharp mx3640n常见故障代码描述,英文手册3

· sharp mx3640n常见故障代码描述,英文手册2

· sharp mx3640n常见故障代码描述,英文手册1

· sharp mx3650fn常见故障代码描述,英文手册4

· sharp mx3650fn常见故障代码描述,英文手册3

· sharp mx3650fn常见故障代码描述,英文手册2

· sharp mx3650fn常见故障代码描述,英文手册1

· sharp mx4050n常见故障代码描述,英文手册4

· sharp mx4050n常见故障代码描述,英文手册3

推荐文章
· sharp进入工厂模式

· sharp ar-2008 d 出现f2,问题原因

· sharp4018打印机小三角灯一直闪问题

· sharpar-4821d打印机出现了那个三角的红色一直亮着怎么回事

· sharpmx-m2608n无法网络打印,设置方法

· toshiba2830显示c970故障代码

· sharpmx-m850打印机出错代码:f2-00怎清除

· sharp2608复印机错误代码l4-11是什么意思怎么解决

· sharp打印机型号是:ar1808s,最近经常出现2f现象,请问是什状况呀?

· sharp2608复印机怎么清除f2-40代码

· toshiba打印机3040c请求维修ce40什么意思

· toshiba复印机错误代码2e66什么意思

· sharpdx-2008uc错误代码f2-40是什么意思

· sharpm2608n无法连接设备请查看设备是否处于扫描模式

· 施乐扫描错误异常结束(018-543)sharednameerrorinserver

· sharpar2348n显示错误

· sharpar2348n常见问题报错解决方法带图文

· sharpar2048s问题大全

· shngc-1202-00下载

· sharp1808s扫描仪显示u-2

· sharp2048n呼叫维修

· sharp2348n恢复出厂

· sharp打印机出现错误代码h5-1是设么意思

· sharp打印复印一体机上面显示有个人的形状然后红灯了是什么意思

· 东芝(toshiba)a4多功能一体机e-studio300d加粉流程图

· sharp2618nc发生错误。代码:l4-43

· sharpar2048打印机显示需要用户干预打印不成怎么办

· toshiba2303卡纸怎去除

· 东芝toshiba2303a打印机提示简易设置调整错误请按确定键重试

· sharp-mx2018uc 报l14-04代码,那位大师指点一下

· toshiba2303a复印机出现e140代码是什么意思

· sharp ar2008d打印清楚。复印很淡,手动清楚,调整方法

· sharp1808s扫描出现u-2

· toshibastudio2303a换碳粉

· sharp mxm700u常见故障代码描述,英文手册2

· sharp mxm654fn常见故障代码描述,英文手册1

· sharp mxm654fn常见故障代码描述,英文手册2

· sharp mxm654fn常见故障代码描述,英文手册3

· sharp mxm623u常见故障代码描述,英文手册1

· sharp mxm623u常见故障代码描述,英文手册2

· sharp mxm620u常见故障代码描述,英文手册01

· sharp mxm620u常见故障代码描述,英文手册02

· sharp mxm564n常见故障代码描述,英文手册01

· sharp mxm564n常见故障代码描述,英文手册02

· sharp mxm550u常见故障代码描述,英文手册01

· sharp mxm550u常见故障代码描述,英文手册02

· sharp mxm503n常见故障代码描述,英文手册1

· sharp mxm503n常见故障代码描述,英文手册2

· sharp mxm502n常见故障代码描述,英文手册2

· sharp mxm502n常见故障代码描述,英文手册1