Code: SC542
Description:
Fusing Reload Temperature Error (Fatal Error) (C8)
Causes:
After starting up or during operation the machine detected after 5 readings at 1.5 sec. intervals that the hot roller was 5 below the reload (operating) temperature. Unstable input voltage Fusing thermistor deformed or out of position Fusing lamp harness loose, broken, defective Fusing lamp defective Fusing unit defective
Remedy:
Use high quality power source Check the Fusing thermistor position and it harness connection Check the Fusing lamp and it harness connection Replace Fusing unit