惠普452dw打印机报错59.F0
更新时间:2024/3/24 10:22:57,view:224惠普452dw苏州惠普通安复印机维修服务中心电话0512-696l6769,苏州惠普452dw通安维修站,惠普452dw通安维修站, 惠普1108报50.0, 惠普打印机后挡盖处于打开, 惠普176N错误50.7, 惠普1020plus定影膜有折痕, 惠普m128显示门已打开,
59.F0 error
59.F0 error ITB Contact Alienation error
Code 59.F0
Display
59.F0 ERROR
Description Transfer alienation failure
Remedy
1. Verify that the ITB is installed.
2. Reconnect the primary-transfer disengagement sensor J19, and connector J128 on the DC controller PCA .
3. Run the sensor test in the sensor monitor mode to verify that the primary transfer disengagement sensor is functioning properly. If not, replace the primary transfer disengagement sensor.
4. Perform the alienation drive component test in the DIAGNOSTICS menu. If not, replace the fuser motor.惠普452dw打印机报错59.F0