Code SC556(定影单元异常)
Description
Pressure roller fusing lamp temperature fluctuation The pressure roller temperature changes by ±20°C or more in one second. This occurs three times in one minute or two consecutive times.
Causes
Loose connection of the pressure roller thermistor
Loose connection between the fusing unit and main frame
Remedy
1. Check if the fusing unit is properly set and connected to the main frame.
2. Check if the pressure roller thermistor connector is firmly connected.
3. Replace the fusing unit.