东芝2008 复印机出现:请求维修,C414是怎回事
定影坏了。需要维修 东芝常见故障问题解答 龙 2015-8-20 16:40:18
打印机出现请求维修C415是哪里的问题
东芝常见故障问题解答 2015-8-21 6:53:09
定影器不预热,检查响应的部件
东芝苏州维修站 2017/2/18 19:43:57
出现安装处理单元,原因是把主板电池拔了,还有这个机子前面出现错误C414
印了15000业出代码c414用084000清不掉
检查定影部件是否异常,如果不是异常的话清除就可以了,08-2002设置为0就可以了
东芝2008 褚楼遍 2018-12-19 Code C414
Description Fuser unit related service call. Thermistor abnormality during warming up or in ready status after abnormality judgment.
Causes MAIN board Thermistors Heater lamp
Remedy
1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?)
2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter
3 Check the thermistors
1. Check if the connectors are disconnected.
2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly?
3. Check if the center and edge thermistors are not deformed or dirty.
4. Check if the harnesses of the center and edge thermistors are open circuited.
4 Check the heater
1. Check if the heater is broken.
2. Check if the connector of the heater is disconnected.
3. Check if the harnesses are connected properly to the terminals of the heater lamp.
4. Check if the thermostat is blown.
5 Check the MAIN board
1. Check if the connectors are disconnected.
2. Check if the conductor pattern on the MAIN board is short circuited or open circuited.
3. Replace the MAIN board.
定影坏了。需要维修 东芝常见故障问题解答 龙 2015-8-20 16:40:18
打印机出现请求维修C415是哪里的问题
东芝常见故障问题解答 2015-8-21 6:53:09
定影器不预热,检查响应的部件
东芝苏州维修站 2017/2/18 19:43:57
出现安装处理单元,原因是把主板电池拔了,还有这个机子前面出现错误C414
印了15000业出代码c414用084000清不掉
检查定影部件是否异常,如果不是异常的话清除就可以了,08-2002设置为0就可以了
东芝2008 褚楼遍 2018-12-19 Code C414
Description Fuser unit related service call. Thermistor abnormality during warming up or in ready status after abnormality judgment.
Causes MAIN board Thermistors Heater lamp
Remedy
1 Check the power voltage Check if the power voltage is normal. (Is the voltage during the operation ±10% of the rated voltage?)
2 Check the each elements of error status Check the abnormal thermistors 08-4570-0: Center thermistor 08-4570-1: Side thermistor 08-4570-2: Edge thermistor 08-4570-5: Error counter
3 Check the thermistors
1. Check if the connectors are disconnected.
2. Check if the center and edge thermistors are in contact with the surface of the fuser roller properly?
3. Check if the center and edge thermistors are not deformed or dirty.
4. Check if the harnesses of the center and edge thermistors are open circuited.
4 Check the heater
1. Check if the heater is broken.
2. Check if the connector of the heater is disconnected.
3. Check if the harnesses are connected properly to the terminals of the heater lamp.
4. Check if the thermostat is blown.
5 Check the MAIN board
1. Check if the connectors are disconnected.
2. Check if the conductor pattern on the MAIN board is short circuited or open circuited.
3. Replace the MAIN board.