佳能iR6800 出现代码E00021-0000,故障原因分析
更新时间:2024/4/18 13:50:38,view:887佳能打印机iR6800 苏州佳能打印机售后维修服务中心电话0512-696l6769,苏州佳能维修点电话, 佳能4410打开主电源, 佳能墨盒故障, 佳能6780喷嘴检查, 佳能Mp288换了车架出现E02, 佳能2420提示添加纸张,
E021 can be displayed when an error occurs in the developing rotary.
The detail codes are:
0001: The developing rotary home position cannot be detected.
0002: The intervals of flag detection during rotation is too short or long.
0003: The sensor does not detect the flag when the developing rotary stops at development point
As a result of inspection, it was found that the DC Controller PCB was unable to control the motor because it was faulty.
Workaround :
1. Check whether or not the developing rotary receives any physical load.
Rotate the developing rotary in a counterclockwise direction by hand to see whether it rotates smoothly. If any abnormality is found, eliminate the root cause. No problem is found, go to the Step 2.
2. Make sure that the connectors are securely fitted between J313 on the DC Controller PCB and the Rotary Motor (M8) or there is no pinched wire. No problem is found, go to the Step 3.
3. Replace the DC Controller PCB with a new one. If the symptom still recurs, go to the Step 4.
4. Replace the Rotary Motor with a new one.